-40%

Dental Digital X-ray RVG Sensor Image Sensor VXS2121 Portable X-ray Machine UPS

$ 401.27

Availability: 10 in stock
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Brand: Unbranded
  • Refund will be given as: Money Back
  • Warranty: 1 Year
  • MPN: CG1180300411
  • Effective image area: 20.16*20.16mm
  • Condition: New
  • Input power: 500mW
  • Spatial Resolution: ≥7Lp/mm
  • Intended Use/Discipline: Dental Laboratory
  • Model: XVS2121
  • Restocking Fee: No
  • Item must be returned within: 60 Days
  • Country/Region of Manufacture: China

    Description

    X-ray RVG Sensor Image Sensor VXS2121
    The product is mainly composed of a sensor, an adaptor, a USB connection
    cable and workstation software.
    Working together with an X
    -ray equipment, the Product is
    intended to make X-ray radiography in
    dental
    clinics
    or
    veterinary clinics
    ,Sensor size
    Suitable for child
    (adult single tooth)
    and pets
    .
    Hardware Requirements

    Central Processor: Intel Core i
    3
    or higher
    Internal Memory:
    4
    GB or higher
    Hard Disk:
    80GB
    or higher
    Display: 1280X1024
    USB interface
    :
    two
    Keyboard: One
    Mouse: One
    Software Requirement
    Operating Software

    Windows 7 SP1,8,10 32/64bit
    Runtime: .Net Framework 4.6 or higher, VC++ 2015
    Specification

    Product Name: Image RVG x-ray Sensor
    Product Model

    XVS2121
    Operating Voltage:5VDC
    Input power

    500mW
    Spatial Resolution

    ≥7Lp/mm
    Low contrast resolution

    Able to display holes with 1mm, 1.5mm, 2mm and
    2.5mm diameter on the 0.5mm-thick aluminium foil
    Image uniformity ≤2%
    Effective image area

    20.16*20.16mm
    Sensor
    Size

    26.5mm
    ×
    32mm
    ×
    11.7mm
    Adaptor
    Size

    60mm
    ×
    40mm
    ×
    29.2mm
    Total Cable Length:
    3
    m (sensor cable + control box cable to PC)
    Warranty:1 Year
    Accessory
    :
    Digital
    sensor
    :
    1 Set
    USB cable
    :
    1
    PCS
    U Disk:
    1
    PCS
    Disposable protective sheath
    :
    1 Box

    500

    silicon loop
    :
    1
    PCS
    Sensor holder
    :
    1
    PCS
    Aluminum plate:
    1
    PCS (40*40*6mm)
    Portable X-ray Machine
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays)
    .
    U
    s
    ing a Toshiba
    0.3
    micro-focus tube
    .
    The
    tu
    be voltage
    fre
    quency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    TECHNICAL SPECIFICATIONS

    Tube Voltage
    6
    0
    kV
    Tube Current
    1
    mA
    Time Exposure
    1~~
    9
    s
    High pressure generator
    30
    kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.
    3
    mm(TOSHIBA)
    Charger Input Voltage
    AC1
    1
    0V

    2
    2
    0V
    Supply Frequency
    50
    Hz±1%
    Radiation Leakage
    <2
    0ug
    y/h
    Battery
    24V DC
    8000MA
    Weight
    4.3
    KG
    Dimensions
    37
    cm×
    31
    cm×
    28
    cm (L×W×H)
    Reference of the Angles

    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure

    Tooth
    Adult
    Child
    Central & Lateral
    0
    .
    8
    -
    1.2
    0.8
    -
    1.0
    Cuspid & 1
    st
    Bicuspid
    1.2
    -
    1.4
    1.0
    -
    1.2
    Upper 5

    6
    1.6
    -
    1.8
    1.4
    -
    1.6
    Upper 7

    8
    3.0
    -
    3.5
    2.8
    -
    3.3
    .
    Lower 5

    6
    1.8
    -
    2.0
    .
    1.6
    -
    1.8
    Lower
    7

    8
    2.0
    -
    2
    .5
    1.8
    -
    2.3
    Packing List:
    Main machine
    1pcs
    Power line
    1pcs
    User manual
    1pcs
    Operation of the Main Unit :
    Upon re
    ceiv
    ing

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Install the blue ray tube to the foreside of the ball head

    then tighten it.
    Turn on the Power

    the pilot lamp will be light up
    .
    During this time

    the digital tube will show the fore se
    ttin
    g time. Now the equipment is in standby mode.
    Sett
    ing the time (Skip to next step if unneeded) Use the "SET"

    "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode

    then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode. Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the t
    oot
    h)Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    After exposure to the tube

    press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

    so the dental films can be used again).
    Repeat step 6 to reset the picturing time
    .
    To repeat the picturing process

    please repeat steps 7 to 9.
    Turn the power off when the work is
    finish
    ed

    press POWER

    making sure the pilot lamp is
    off.
    Don't keep the ma
    chine
    long in standby mode.
    Points for Attention:
    Make sure the angle of film

    tooth

    and ball head are properly aligned when taking a picture.
    Keep them steady until the last step of picturing
    ;
    making sure that there is no change in any of their positions.Remember to turn the power 0
    ff
    when work is done.Cha
    r
    ge the battery if t
    he machine cannot work and the red lamp lignt
    After turning the power on

    wait one minute before taking pictures

    this allows the ray to provide a steady ou
    tp
    ut.The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

    it will not be able to carry out the normal work of
    fil
    ming.When taking pictures

    the
    ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.Handle the ball head gently while in use

    so as not to damage the delicate component.
    We usually set the time between 3-8 seconds when taking pictur
    es

    but the actual time of ray output is 0.2-0.5 seconds.If a situation occurs

    preventing the machine from taking regular pictures

    contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality. Other r
    eq
    ues
    ts
    accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    Seller name:Dentaljoy
    City,State:SHENZHEN,China
    Telephone number:0755-67530378
    STATEMENT :
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.  If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    Payment
    We only accept paypal payment,it is easy and safe. and for any other payment forms,please kindly contact us in advance.
    Shipping
    The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
    General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)
    About Us
    If you have any query or dissatisfaction, please find our customer service via eBay Message Center only.
    If you send message via eBay message, we'll reply you within 24 working hours.
    Thank you so much for your purchase. Wish you have a nice day! : -)