-40%
Dental X Ray Imaging System Digital X-Ray Sensor USB 2.0 Connection Cable Oral
$ 333.66
- Description
- Size Guide
Description
Store categorySign Up Now !
You may also like
Dental X Ray Imaging System Digital X-Ray Sensor USB 2.0 Connection Cable Oral
Product Description
Operating Voltage
5VDC
Input power
500mW
Spatial Resolution
≥7Lp/mm
Low contrast resolution
Able to display holes with 1mm, 1.5mm, 2mm and
Image uniformity
≤2%
Effective image area
20.16*20.16mm
Sensor Size
26.5mm×32mm×11.7mm
Adaptor Size
60mm×40mm×29.2mm
Total Cable Length
3 m (sensor cable + control box cable to PC)
Brand
BODE
MPN
Does Not Apply
Discription:
The intraoral sensor is the key component for imaging. It converts the X-ray signals into electrical signals that will be
transmitted to the acquisition workstation. The sensor is connected to the workstation via the USB 2.0 connection.
Before connecting the sensor, do not start the acquisition workstation software. Do not disconnect the sensor during the image acquisition
process, otherwise the sensor can be damaged.
Notice:
1. The digital intraoral X-ray sensor is compatible with relating electromagnetic
compatibility requirements laid down in IEC60601-1-2;
2. The user should install and use the product according to the electromagnetic
compatibility requirements laid down in the documents with shipment;
3. Portable or mobile RF communicaion devices might affect the products performance.
When using the product, avoiding strong electromagnetic interference, like being cclose
to mobile phones, microwaves or etc.;
4. For guidance and manufacturer's statements, refer to the appendixes.
5. The troulbeshooting in the appendix also applies to the electromagnetic
compatibility test. If trouble occurs, refer to appendex; trouble shooting.
Product Components:
The products is mainly composed of a sensor, an adaptor, a USB connection cable
and workstation software. Other standard accessories include a box of protective
sheath, a silicon loop and a sensor holder.
Payment
About shipping
Statement(FDA)
Contact us
Positive feedback
Payment
We accept PAYPAL payment. Payment should be sent within 7 business days.
About shipping
We usually ship item by economic post air mail. It usually takes approximately 15-30 business days. Somtimes, it might take much longer time because of customs things. If you want express shipping such as DHL, EMS etc,please contact with us.
Statement(FDA)
Statement(FDA)
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Contact us
For any questions before and after sale, please leave us ebay message, and we will do our best to resolve them.
Positive feedback
Please leave us a positive feedback to us if you feel our product & service is ok, our system will do the same to you automatically.
Feedback